Sign in →

Glucose Level Random  

Additional Codes

LAB82

Performing Laboratory

MBMC Main Laboratory

Methodology

UV-Hexokinase

Specimen Requirements

Note: This test is also available as part of Basic Metabolic Profile, Comprehensive Metabolic Profile, and Renal Panel. See Common Panel Test Combinations in Special Instructions to avoid duplicate test requests when multiple panels are ordered.

 

Specimen Type: Plasma
Container/Tube: Mint-green top (lithium heparin gel)
Alternative Container/Tube: Gray top (potassium oxalate/sodium fluoride)

Alternative Specimen Type:  Serum

Alternative Container/ Tube: Gold, Serum gel

Specimen Volume: Full tube

Specimen Transport Temperature

Ambient

Day(s) Test Set Up

Monday through Sunday
Turnaround Time:
STAT: 1 hour after receipt in laboratory
Routine: within 4 hours

Reference Values

Age Range

Units

Reference Low

Reference High

Critical Low

Critical High

0

minutes

3

days

mg/dL

50

110

<44

>450

4

days

150

years

mg/dL

70

199

<54

>450

Critical values (automatic call-back):

0 - 3 days:   <44 or > 450 mg/dL

4 days - 150 years:  <54 or >450 mg/dL

Interpretive Data: 

Fasting glucose is defined as no caloric intake for at least 8 hours.

Fasting glucose  > 126 mg/dL is diagnostic for diabetes

Fasting values  between 100-125 mg/dL is diagnostic of prediabetes.

In a patient with classic symptoms of hyperglycemia or haperglycemic crisis, a random glucose > 200 mg/dL is diagnostic for diabetes.

In the absence of unequivocal hyperglycemia, results should be confirmed by repeat testing. 

 

The classification and Diagnosis of Diabetes:

Diabetes Care 2022; 46, Supplement: S19-S40.

Current interpretive data was revised 01.16.2023

 

Test Classification and CPT Coding

 

Test Classification:This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer’s instructions.
CPT Code:
82947

 

Stability

Mint top or Gold:  3 days Refrigerated

Gray top tube:  5 days Refrigerated