Sign in →

Protein Total Level, Body Fluid  

Additional Codes

LAB196

Performing Laboratory

MBMC Main Laboratory

Methodology

Turbidimetric- benzethonium chloride

Specimen Requirements

Specimen Type: Body fluid
Container/Tube: Sterile container or plain, red-top tube
Specimen Minimum Volume: 2 mL
Additional Information: Indicate specimen source.  Testing will only be performed on these fluids:  Pleural, Abdominal (pancreatic, peritoneal) and Pericardial.

Specimen Transport Temperature

Ambient

Day(s) Test Set Up

Monday through Sunday
Turnaround Time:
STAT: 1 hour after receipt in laboratory
Routine: within 4 hours

Reference Values

No established reference values

Test Classification and CPT Coding

 

Test Classification:This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer’s instructions.
CPT Code:

 

84157