Mutated Citrullinated Vimentin (MCV) Antibody
Additional Codes
LAB52605
Performing Laboratory
Quest Diagnostics
Methodology
Enzyme Linked Immunosorbent Assay (ELISA)
Specimen Requirements
Specimen Type: Serum
Container/Tube: Plain red top
Alternative Container/Tube: Gold, Serum gel
Specimen Volume: Full tube
Preferred Specimen(s)
1.0 mL serum
Minimum Volume
0.5 mL
Transport Container
Transport tube
Specimen Transport Temperature
Transport Temperature
Room temperature
Specimen Stability
- Room temperature: 7 days
Refrigerated: 14 days
Frozen: 6 months
Day(s) Test Set Up
Set up: Daily; Report available: 1-3 days
Reference Values
<20 U/mL
Test Classification and CPT Coding
83520