Von Willebrand Factor (VWF) Multimers
Additional Codes
LAB1111
Quest Test Code: 5168
Performing Laboratory
Quest Diagnostics Nichols Institute-Chantilly VA
Methodology
Electrophoresis
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Specimen Requirements
1 mL frozen platelet-poor plasma collected in a 3.2% sodium citrate (light blue-top) tube
Minimum Volume
0.5 mL
Collection Instructions
Platelet-poor plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice.
Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies
Specimen Transport Temperature
Specimen Stability
Room temperature: Unacceptable
Refrigerated: Unacceptable
Frozen -70° C: 6 months
Reject Criteria
Hemolysis • Thawed plasma received room temperature or refrigerated
Day(s) Test Set Up
Set up: Mon-Thurs a.m.; Report available: 4-7 days
Reference Values
Normal
Test Classification and CPT Coding
85247