Test Code LAB311 Antithrombin Activity, Blood
Additional Codes
LAB311
Methodology
Chromogenic
Literature References:
Package insert: HemosIL Liquid Antithrombin Kit (pn20030100) Instrumentation Laboratory, issued 08/2014.
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Specimen Requirements
Specimen Type: Blood
Container/Tube: Light-blue top (citrate) tube.
Specimen Volume: Full tube
Specimen Minimum Volume: Full tube
Collection Instructions:
- Draw a discard blue top tube prior to drawing a light-blue top (citrated) tube if using a Winged Infusion Set. Discard tube should be under filled and discarded.
- Clotted blood or an insufficient specimen is not acceptable.
- Avoid phlebotomy techniques which cause hemolysis and heparin contamination.
- Follow nursing policy on volume of blood to discard prior to collecting blood from indwelling heparinized catheters.
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Additional Information:
If the patient is a hospital patient and the hematocrit is >55%, call Barnes-Jewish Hematology Laboratory at 314-362-5203 for instructions.
Specimen Transport Temperature
Ambient Yes/Refrigerate NO/Frozen Yes
Reference Values
80%-125%
Literature References:
1. Egeberg O. Inherited antithrombin deficiency causing thrombophilia. Thromb Diath Haemorrh 1965;13:516-30.
2. Fareed J, Messmore HL, Walenga JM, et al. Laboratory evaluation of antithrombin III: a critical overview of currently available methods for antithrombin III measurements. Semi Thromb Hemost 1982;8(4):288-301.
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT: 1 hour after receipt in laboratory
Routine: 2-4 hours after receipt in laboratory
Test Classification and CPT Coding
85300
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
4 hours at 18° C to 24° C.
Platelet-free plasma can be frozen at -20 for transport on dry ice up to 72 hours
or stored 6 months at -70° C.
Laboratory Processing Instructions:
Test performed in BJH Core Lab.
LOINC Code Information
Name | LOINC Code |
Antithrombin Activity, Blood | 3174-0 |