Test Code Lab318 Platelet Function Screen
Additional Codes
LAB318
Methodology
Platelet Adhesion to Biochemically Active Membranes
Performing Laboratory
Barnes-Jewish Hospital Laboratory
Specimen Requirements
Specimen Type: Whole blood
Container/Tube: Light-blue top (citrate)
Specimen Volume: Full tube
Specimen Minimum Volume: Full tube
Collection Instructions:
- Draw a discard blue top tube prior to drawing a light-blue top (citrated) tube if using a Winged Infusion Set. Discard tube should be under filled and discarded.
- Clotted blood or an insufficient specimen is not acceptable.
- Avoid phlebotomy techniques which cause hemolysis and heparin contamination.
- Follow nursing policy on volume of blood to discard prior to collecting blood from indwelling heparinized catheters.
- DO NOT send tube through the pneumatic tube station.
Analyte Stability:
4 hours at 18° C to 24° C.
Specimen Transport Temperature
Ambient/Refrigerate NO/Frozen NO
Reference Values
Collagen/Epinephrine: 60-160 seconds
Collagen/ADP: 50-110 seconds
An interpretive comment will be provided.
Literature References:
1. Instrument manual: PFA-100 Platelet function analyzer. Dade Behring, 2002.
2. Kundu SK, Heilmann EJ, Sio R, Garcia C. Characterization of an in vitro platelet function analyzer, PFA-100. Clin Appl Thromb Hemost 1996;2:241-9.
3. Stasik J. Newspath: Principles, indication and limitations of the platelet function analyzer. 08/2006.
Day(s) Test Set Up
Monday through Sunday
Turnaround Time:
STAT: 1 hour after receipt in laboratory
Routine: 2-4 hours after receipt in laboratory
Test Classification and CPT Coding
85576 x 2
Additional Information
For BJH Laboratory Use Only
Analyte Stability:
4 hours at ambient temperature
Laboratory Processing Instructions:
Test is performed in BJH Core Lab. Do not refrigerate or centrifuge specimen. Specimen arriving via pneumatic tube system is not suitable for testing.
LOINC Code Information
Name | LOINC Code |
Platelet Function | 49010-2 |
Platelet Function Interpretation | 49836-0 |